Electron density and Faraday rotation angle are important physical parameters in nuclear fusion research. To measure them simultaneously, the three-wave polarimeter/interferometer diagnostic system is applied. Both the final probe output signal and the reference signal contain three frequency components. The time-varying phase difference curve of each frequency component can be measured by the Real-time Dynamic Spectrum Analysis (RDSA) method based on Field-Programmable Gate Array (FPGA). The phase difference precision is better than 0.1° and the real-time feedback delay is less than 1 ms, which satisfy the requirements of HL-2A.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 1092-1096 |
| 页数 | 5 |
| 期刊 | Plasma Science and Technology |
| 卷 | 17 |
| 期 | 12 |
| DOI | |
| 出版状态 | 已出版 - 12月 2015 |
| 已对外发布 | 是 |