A Biomedical Sensor Network (BSN) is a small-size sensor network for medical applications, that may contain tens of sensor nodes. In this paper, we present a formal model for BSNs using timed automata, where the sensor nodes communicate using the Chipcon CC2420 transceiver (developed by Texas Instruments) according to the IEEE 802.15.4 standard. Based on the model, we have used UPPAAL to validate and tune the temporal configuration parameters of a BSN in order to meet desired QoS requirements on network connectivity, packet delivery ratio and end-to-end delay. The network studied allows dynamic reconfigurations of the network topology due to the temporally switching of sensor nodes to power-down mode for energy-saving or their physical movements. Both the simulator and model-checker of UPPAAL are used to analyze the average-case and worst-case behaviors. To enhance the scalability of the tool, we have implemented a (new text-based) version of the UPPAAL simulator optimized for exploring symbolic traces of automata containing large data structures such as matrices. Our experiments show that even though the main feature of the tool is model checking, it is also a promising and competitive tool for efficient simulation and parameter tuning. The simulator scales well; it can easily handle up to 50 nodes in our experiments. The model checker installed on a notebook can also deal with networks with 5 up to 16 nodes within minutes depending on the properties checked; these are BSNs of reasonable size for medical applications. Finally, to study the accuracy of our model and analysis results, we compare simulation results by UPPAAL for two medical scenarios with traditional simulation techniques using OMNeT++, one of the most used simulation tools for wireless sensor networks. The comparison shows that our analysis results coincide with the simulation results by OMNeT++ in most cases although there are some differences caused the simplified wireless channel model in UPPAAL.

源语言英语
主期刊名Proceedings of the 8th ACM International Conference on Embedded Software, EMSOFT'08
出版商Association for Computing Machinery (ACM)
69-78
页数10
ISBN(印刷版)9781605584683
DOI
出版状态已出版 - 2008
已对外发布
活动8th ACM International Conference on Embedded Software, EMSOFT 2008 - Atlanta, GA, 美国
期限: 19 10月 200824 10月 2008

出版系列

姓名Proceedings of the 8th ACM International Conference on Embedded Software, EMSOFT'08

会议

会议8th ACM International Conference on Embedded Software, EMSOFT 2008
国家/地区美国
Atlanta, GA
时期19/10/0824/10/08

指纹

探究 'Model-based validation of QoS properties of Biomedical Sensor networks' 的科研主题。它们共同构成独一无二的指纹。

引用此