跳到主要导航 跳到搜索 跳到主要内容

Mechanical and optical design of the FIR laser Polarimeter/Interferometer on the HL-3 tokamak

  • Y. G. Li*
  • , Yuan Li
  • , J. R. Mou
  • , X. Y. Gu
  • , H. X. Wang
  • , Z. H. Wang
  • , P. F. Zhang
  • , J. Yi
  • , B. G. Ding
  • , J. Q. Xu
  • , Z. B. Shi
  • , W. Chen
  • , W. L. Zhong
  • *此作品的通讯作者
  • Southwestern Institute of Physics

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Aiming to achieve important parameters of the electron density and plasma current density profile, a multi-channel far-infrared (FIR) laser Polarimeter/Interferometer is being developed for HL-3 tokamak by using the formic-acid laser source (HCOOH, λ=432.5 μm). All the 13 probing channels were distributed in two columns, including eight horizontally-viewing channels and five oblique channels. The stainless steel support tower (7.0 m high) was specially designed, and itself novel structure allowed us to arrange the light-paths of horizontal channels and oblique channels on two sides, respectively. Copper corner-cube-reflector (CCR) was mounted in the vacuum vessel to retrace the incident wave. In 2023, multi-channel line-integral electron densities were successfully derived by the interferometric measurement, with a time resolution of 1.0μs, line-integral density resolution of ∼5.0 × 1016/cm2. Right now, the interferometer system is being upgraded to three-wave based Polarimeter/Interferometer, which is able to simultaneously measure the electron density and Faraday rotation angle.

源语言英语
期刊论文编号114489
期刊Fusion Engineering and Design
卷204
DOI
出版状态已出版 - 7月 2024

学术指纹

探究 'Mechanical and optical design of the FIR laser Polarimeter/Interferometer on the HL-3 tokamak' 的科研主题。它们共同构成独一无二的学术指纹。

引用此