跳到主要导航 跳到搜索 跳到主要内容

Long-term reliability of silicon wafer-based traditional backsheet modules and double glass modules

  • East China Normal University
  • Ltd.

科研成果: 期刊稿件文章同行评审

摘要

An extensive program of series extended sequential long-term reliability stress including thermal cycling (TC) 600, damp heat (DH) 3000, 600 hours potential induced degradation (PID) and humidity freeze (HF) 50 were performed on silicon wafer-based traditional backsheet modules and double glass photovoltaic (PV) modules. The relative module maximum power (Pmax) degradations of traditional backsheet modules are 3.87%, 7.34%, 13.3%, 33.73% and those of double glass modules are 2.78%, 3.12%, 2.27%, 2.72%, respectively. From all the above results, HF50 has a greater impact on Pmax degradation of traditional backsheet modules, and a strong correlation is thereby found between the Water Vapor Transmission Rate (WVTR) of the backsheet and the Pmax degradation. Traditional backsheet modules have higher WVTR and greater Pmax degradation, while double glass modules are impermeable and have much lower Pmax degradation. The key factor for excellent performance of Si wafer-based double glass PV modules is replacing the polymer backsheet by a glass panel with impermeability to water vapor, which enables double glass modules to offer much higher reliability and longer durability.