跳到主要导航 跳到搜索 跳到主要内容

Influences of hydraulic loading rate on SVOC removal and microbial community structure in drinking water treatment biofilters

  • Xu Xiang Zhang
  • , Zong Yao Zhang
  • , Li Ping Ma
  • , Ning Liu*
  • , Bing Wu
  • , Yan Zhang
  • , Ai Min Li
  • , Shu Pei Cheng
  • *此作品的通讯作者
  • Nanjing University

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Six biofilters were used for advanced treatment of Yangtze River source water to investigate the effects of hydraulic loading rate (HLR) on pollutant removal and microbial community. HLR was found to exert significant influences on the removal efficiency of the conventional pollutants and 24 detectable semivolatile organic compounds (SVOCs). More than 85% of chemical oxygen demand and assimilable organic carbon was removed at the optimal HLR of 3.0mh-1. With the increase of HLR, SVOC removal showed a decreasing trend. Di-n-butyl phthalate and bis(2-ethylhexyl)phthalate, two main SVOCs in the source water, had the highest removals of 71.2% and 84.4%, respectively. Nearly 65% of 2,6-dinitrotoluene and 80% of isophorone were removed at the lowest HLR. Phylogenetic analysis showed that Escherichia coli, Shigella sp., E. fergusonii and Firmicutes bacteria predominated in the bioreactors. The dominance of E. coli in the low-HLR biofilters might contribute greatly to the high SVOC removal.

源语言英语
页(从-至)652-657
页数6
期刊Journal of Hazardous Materials
卷178
期1-3
DOI
出版状态已出版 - 6月 2010
已对外发布是

学术指纹

探究 'Influences of hydraulic loading rate on SVOC removal and microbial community structure in drinking water treatment biofilters' 的科研主题。它们共同构成独一无二的学术指纹。

引用此