跳到主要导航 跳到搜索 跳到主要内容

Impedance Monitoring of SH-SY5Y Cell Adhesion and Responses to As2O3 Treatment by Indium Tin Oxide Microelectrode Arrays

  • Hui Zhao
  • , Fan Zhang*
  • , Pingang He
  • *此作品的通讯作者
  • East China Normal University
  • Zhoukou Normal University

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

For most of the cells, cell adhesion is one of the essential factors for cell growth in vitro. In this paper, the impedance was used to monitor SH-SY5Y cell adhesion and evaluate the responses to As2O3 in a real-time, noninvasive, and label-free manner with indium tin oxide microelectrode arrays. Due to the transparency of the electrodes, cell activities can be observed simultaneously when impedance monitoring proceeded. The results indicated that the impedance responses had a good correlation with microscopic analysis of cell activities. Moreover, As2O3 at different concentrations were added for the evaluation of its effect on cell adhesion. 40μ mol/L As2O3 could detach almost all of the cells from the microelectrode surface, leading to an obvious decrease in impedance responses and declined cell survival rate after 9 h of treatment. Importantly, the impedance monitoring can provide the information about cell adhesion changes much earlier than commonly used cell microphotographs determination. This paper indicated the convenience and sensitivity of impedance for the direct and real-time monitoring of cell behaviors and drug-induced cell activities in vitro. It may be a driving force for the study of As2O3 effect on neuroblastoma and provides a useful and non-invasive analytical approach for cancer research.

源语言英语
期刊论文编号7984781
页(从-至)5426-5430
页数5
期刊IEEE Sensors Journal
卷17
期17
DOI
出版状态已出版 - 1 9月 2017

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 3 - 良好健康与福祉
    可持续发展目标 3 良好健康与福祉

学术指纹

探究 'Impedance Monitoring of SH-SY5Y Cell Adhesion and Responses to As2O3 Treatment by Indium Tin Oxide Microelectrode Arrays' 的科研主题。它们共同构成独一无二的学术指纹。

引用此