摘要
A novel method for the oxidative determination of trace arsenic(III) was investigated on highly ordered platinum-nanotube array electrodes (PtNTAEs). The PtNTAEs with a highly organized structure were fabricated by electrochemical deposition of platinum in a 3-aminopropyltrimethoxysilane-modified porous anodic alumina template (PAA). The morphologies and structures of PtNTAEs were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Electrochemical experiments proved that the PtNTAEs exhibited better performance for As(III) analysis in comparison with platinum nanoparticles-coated GCE (Ptnano/GCE) or Pt foil electrode. The PtNTAEs showed to provide higher reproducibility and lower detection limit. The relative standard deviation (RSD) was 3.5% for 50 repeated measurements of 20 μM As(III), and the limit of detection (LOD) was 0.1 ppb, which was typically 1-2 orders of magnitude lower than that of Ptnano/GCE or Pt foil electrode.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 1893-1896 |
| 页数 | 4 |
| 期刊 | Electrochemistry Communications |
| 卷 | 10 |
| 期 | 12 |
| DOI | |
| 出版状态 | 已出版 - 12月 2008 |