跳到主要导航 跳到搜索 跳到主要内容

High performance liquid chromatography-electrochemical detection (HPLC-ECD) for the pharmacokinetic studies of acetaminophen with microdialysis

  • Guoyue Shi*
  • , Fang Xu
  • , Jian Xue
  • , Litong Jin
  • *此作品的通讯作者
  • East China Normal University

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

In this article, we combined microdialysis sampling with HPLC-ECD and studied the pharmacokinetics of acetaminophen. In the mobile phase of phosphate buffer solution (PBS, pH 7.0), the copper tetraaminophthalocyanine (CuTAPC) chemically modified electrode, which was used as working electrode, has good electrocatalytical oxidation of acetaminophen with a detection limit of 2.0 × 10-7 mol/L and a linear concentration range of 6.0 × 10-7 mol/L-1.0 × 10-4 mol/L at +500 mV (vs. Ag/AgCl). In vivo microdialysis is an excellent complement to directly monitor chemical events in different organs and has been widely used for many fields. We applied this method to study the pharmacokinetic of acetaminophen (ACE). The estimated association constant (K) and the number of the binding sites (n) on one molecule of BSA were 5.37 × 103 (mol/L)-1 and 2.57, respectively. The calculated half-life of absorption was 33.0 ± 1.0 min, and that of elimination was 45.0 ± 2.0 min.

源语言英语
页(从-至)432-437
页数6
期刊Electroanalysis
卷11
期6
DOI
出版状态已出版 - 5月 1999

学术指纹

探究 'High performance liquid chromatography-electrochemical detection (HPLC-ECD) for the pharmacokinetic studies of acetaminophen with microdialysis' 的科研主题。它们共同构成独一无二的学术指纹。

引用此