跳到主要导航 跳到搜索 跳到主要内容

Fouling of proton exchange membrane (PEM) deteriorates the performance of microbial fuel cell

  • Juan Xu
  • , Guo Ping Sheng*
  • , Hong Wei Luo
  • , Wen Wei Li
  • , Long Fei Wang
  • , Han Qing Yu
  • *此作品的通讯作者
  • University of Science and Technology of China

科研成果: 期刊稿件文章同行评审

摘要

The fouling characteristics of proton exchange membrane (PEM) in microbial fuel cell (MFC) and the resulting deterioration of MFC performance were explored in this study. It was observed that the ion exchange capacity, conductivity and diffusion coefficients of cations of PEM were reduced significantly after fouling. Imaging analysis coupled with FTIR analysis indicated that the fouling layer attached on PEM consisted of microorganisms encased in extracellular polymers and inorganic salt precipitations. The results clearly demonstrate that PEM fouling deteriorated the performance of MFCs and led to a decrease in electricity generation. Cation transfer limitation might play an important role in the deterioration of MFC performance because of the membrane fouling. This was attributed to the physical blockage of charge transfer in the MFC resulted from the membrane fouling. With the experimental results, the effect of membrane fouling on the electrical generation of MFCs was evaluated. It was found that the decreased diffusion coefficients of cations and cathodic potential loss after membrane fouling contributed mainly to the deterioration of the MFC performance.

源语言英语
页(从-至)1817-1824
页数8
期刊Water Research
46
6
DOI
出版状态已出版 - 15 4月 2012