摘要
Accurate momentum determination of a neutral hadron, such as a KL meson or a neutron, remains a significant challenge in particle physics and nuclear physics experiments. The Belle II experiment presents an opportunity to address this challenge through an upgrade incorporating Time-of-Flight (TOF) capability for its large KL and Muon Detector (KLM). We investigated the feasibility of momentum determination via TOF measurement. To achieve high time resolution for the KLM upgrade, we conducted research and development of cost-effective plastic scintillators and silicon photomultiplier arrays. A bulk attenuation length of 120±7cm has been achieved with a 135cm-long bar, along with a time resolution of 70±7ps at its midpoint. A 50cm-long scintillator demonstrates an exceptional time resolution of 47±2ps. These results highlight the potential of the proposed technology for improving neutral hadron momentum measurements in an upgraded Belle II KLM detector.
| 源语言 | 英语 |
|---|---|
| 期刊论文编号 | 171194 |
| 期刊 | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
| 卷 | 1084 |
| DOI | |
| 出版状态 | 已出版 - 4月 2026 |
| 已对外发布 | 是 |
学术指纹
探究 'Development of a high resolution Time-of-Flight with SiPM-readout Scintillator in Belle II for measurement of Neutral Hadron momentum' 的科研主题。它们共同构成独一无二的学术指纹。引用此