Deep learning enhanced ultra-fast SPECT/CT bone scan in patients with suspected malignancy: quantitative assessment and clinical performance

  • Na Qi
  • , Boyang Pan
  • , Qingyuan Meng
  • , Yihong Yang
  • , Tao Feng
  • , Hui Liu
  • , Nan Jie Gong
  • , Jun Zhao*
  • *此作品的通讯作者
  • Tongji University
  • RadioDynamic Healthcare
  • Tsinghua University

科研成果: 期刊稿件文章同行评审

摘要

Objectives. To evaluate the clinical performance of deep learning-enhanced ultrafast single photon emission computed tomography/computed tomography (SPECT/CT) bone scans in patients with suspected malignancy. Approach. In this prospective study, 102 patients with potential malignancy were enrolled and underwent a 20 min SPECT/CT and a 3 min SPECT scan. A deep learning model was applied to generate algorithm-enhanced images (3 min DL SPECT). The reference modality was the 20 min SPECT/CT scan. Two reviewers independently evaluated general image quality, Tc-99m MDP distribution, artifacts, and diagnostic confidence of 20 min SPECT/CT, 3 min SPECT/CT, and 3 min DL SPECT/CT images. The sensitivity, specificity, accuracy, and interobserver agreement were calculated. The lesion maximum standard uptake value (SUVmax) of the 3 min DL and 20 min SPECT/CT images was analyzed. The peak signal-to-noise ratio (PSNR) and structure similarity index measure (SSIM) were evaluated. Main results. The 3 min DL SPECT/CT images showed significantly superior general image quality, Tc-99m MDP distribution, artifacts, and diagnostic confidence than the 20 min SPECT/CT images (P < 0.0001). The diagnostic performance of the 20 min and 3 min DL SPECT/CT images was similar for reviewer 1 (paired X 2 = 0.333, P = 0.564) and reviewer 2 (paired X 2 = 0.05, P = 0.823). The diagnosis results for the 20 min (kappa = 0.822) and 3 min DL (kappa = 0.732) SPECT/CT images showed high interobserver agreement. The 3 min DL SPECT/CT images had significantly higher PSNR and SSIM than the 3 min SPECT/CT images (51.44 versus 38.44, P < 0.0001; 0.863 versus 0.752, P < 0.0001). The SUVmax of the 3 min DL and 20 min SPECT/CT images showed a strong linear relationship (r = 0.991; P < 0.0001). Significance. Ultrafast SPECT/CT with a 1/7 acquisition time can be enhanced by a deep learning method to achieve comparable image quality and diagnostic value to those of standard acquisition.

源语言英语
文章编号135012
期刊Physics in Medicine and Biology
68
13
DOI
出版状态已出版 - 7 7月 2023
已对外发布

指纹

探究 'Deep learning enhanced ultra-fast SPECT/CT bone scan in patients with suspected malignancy: quantitative assessment and clinical performance' 的科研主题。它们共同构成独一无二的指纹。

引用此