跳到主要导航 跳到搜索 跳到主要内容

A VUV photoionization organic aerosol mass spectrometric study with synchrotron radiation

  • Wenzheng Fang
  • , Gong Lei
  • , Xiaobin Shan
  • , Fuyi Liu
  • , Zhenya Wang
  • , Liusi Sheng*
  • *此作品的通讯作者
  • University of Science and Technology of China
  • CAS - Anhui Institute of Optics and Fine Mechanics

科研成果: 期刊稿件文章同行评审

摘要

A photoionization aerosol time-of-flight mass spectrometer (ATOFMS) has been developed for on-line analysis of organic compounds in aerosol particles using tunable vacuum ultraviolet (VUV) synchrotron radiation. Aerosol particles can be sampled directly from atmospheric pressure and are focused through an aerodynamic lens assembly into the mass spectrometer. The particles are vaporized when they impact on a heater, and then the nascent vapor is softly photoionized by synchrotron radiation. The degree of fragmentation of molecule can be controlled either by the heater temperature or by the photon energy. Thus, fragment-free tunable VUV mass spectra are obtained by tuning the photon energy close to the ionization energies (IEs) of the sample molecules. The direct determination of the IEs of benzophenone (9.07 eV), salicylic acid (8.72 eV), and urea (9.85 eV) are measured from the photoionization efficiency spectra with uncertainties of ±50 meV. Ab initio calculations have been employed to predict the theoretical ionization energy.

源语言英语
页(从-至)129-133
页数5
期刊Journal of Electron Spectroscopy and Related Phenomena
184
3-6
DOI
出版状态已出版 - 4月 2011