跳到主要导航 跳到搜索 跳到主要内容

远红外显微成像光学系统的设计与仿真

  • Yue Wang
  • , Aiyun Liu
  • , Wangzhou Shi
  • , Gujin Hu*
  • , Chixian Liu
  • , Changyi Pan
  • , Yufeng Shan
  • , Yi Zhang
  • , Huiyong Deng*
  • , Ning Dai
  • *此作品的通讯作者
  • Shanghai Normal University
  • CAS - Shanghai Institute of Technical Physics

科研成果: 期刊稿件文章同行评审

摘要

This study focuses on the design and simulation of the transmission far infrared microscopic imaging optical system matched with the cooled staring focal plane array detector that operates in the wavelength range of 50—70 μm and contains pixel number 64×64, each pixel is 120 μm×120 μm in size in order to make the far infrared detector obtain optoelectronic signals with a high signal-to-noise ratio. Stray light analysis predicts the negative effect caused by cold reflection, and a solution is proposed to address it. The simulation results show that when the designed optical system’s spatial resolution, numerical aperture, focal length, effective magnification, and central wavelength are 200 μm, 0. 25, 14 mm, 10, and 61 μm, respectively, the modulation transfer function value reaches 0. 305 at the characteristic frequency of 5 lp·mm−1, and the energy concentration of the surrounding circle of the system exceeds 80%. Meanwhile, the optical system’s produced object picture is easily distinguishable, indicating that it meets the functioning criteria of the focal plane array detector.

投稿的翻译标题Design and Simulation of Far Infrared Microscopic Imaging Optical Systems
源语言繁体中文
文章编号1122005
期刊Laser and Optoelectronics Progress
59
11
DOI
出版状态已出版 - 6月 2022
已对外发布

关键词

  • analog simulation
  • far infrared cooled detector
  • microscopy imaging optical system
  • optical design

指纹

探究 '远红外显微成像光学系统的设计与仿真' 的科研主题。它们共同构成独一无二的指纹。