跳到主要导航 跳到搜索 跳到主要内容

等离子体处理制备柔性低损耗 ABS/Ag 太赫兹空芯波导及其传输可靠性研究

科研成果: 期刊稿件文章同行评审

摘要

The performance of ABS/Ag-coated terahertz hollow waveguide(HWG)was improved through plasma treatment of the ABS structural tube. The adhesion of the silver(Ag)film to the ABS tube was enhanced from level 5 to level 2 after plasma treatment. The 4. 2 mm bore waveguide sample treated with plasma has a more uniform and denser silver film than the untreated sample,which contributes to the reduction of transmission losses from 0. 72 dB/m to 0. 70 dB/m at 0. 3 THz and 1. 47 dB/m to 1. 44 dB/m at 0. 1 THz,respectively. After 200 hours of hydrothermal aging and 16 cycles of high and low temperature cycling testing,the straight loss of the HWG sample treated with plasma increased by less than 0. 1 dB/m,while the untreated sample underwent an increase of more than 1. 0 dB/m. The results indicate that the ABS/Ag-coated HWG fabricated by plasma treatment has lower loss,higher reliability and better anti-aging performance compared with the untreated sample. It can be potentially used for establishment of next-generation communication,sensing,and THz imaging systems.

投稿的翻译标题Preparation of flexible low-loss ABS/Ag-coated terahertz hollow waveguide by plasma treatment and study on its transmission reliability
源语言繁体中文
页(从-至)533-540
页数8
期刊Hongwai Yu Haomibo Xuebao/Journal of Infrared and Millimeter Waves
43
4
DOI
出版状态已出版 - 8月 2024

关键词

  • hollow waveguide
  • plasma treatment
  • terahertz transmission
  • terahertz waveguide

指纹

探究 '等离子体处理制备柔性低损耗 ABS/Ag 太赫兹空芯波导及其传输可靠性研究' 的科研主题。它们共同构成独一无二的指纹。

引用此