TY - JOUR
T1 - To what extent are we really free from airborne microplastics?
AU - Song, Zhangyu
AU - Liu, Kai
AU - Wang, Xiaohui
AU - Wei, Nian
AU - Zong, Changxing
AU - Li, Changjun
AU - Jiang, Chunhua
AU - He, Yinan
AU - Li, Daoji
N1 - Publisher Copyright:
© 2020 Elsevier B.V.
PY - 2021/2/1
Y1 - 2021/2/1
N2 - Quality assurance and quality control (QA&QC) procedures are vital for ensuring data reliability, but little is known about the use of such procedures in reducing airborne microplastic (MP) contamination. To address this issue, we tried to determine the efficiency of two common methods (washing and ashing experimental glassware) for removing airborne MPs and identified airborne contamination during MP analytical procedure. The results showed the removal efficiencies of washing and ashing were an average of 88%–98% and 100%, respectively, indicating that both methods could eliminate most of the spiked airborne MPs with no significant difference noted between the two methods. Although rigorous measures were taken to prevent contamination from ambient air, trace amounts of airborne MPs were still detected, which is an issue that has not been adequately investigated in previous studies. All of the procedural contaminants detected in this study were fibrous. Approximately 88% of these fibers were cotton-like (cotton, cellulose, and cellophane) fibers, and 13% of them were plastic. Surprisingly, cotton-like fibers and MPs had a similar size distribution, suggesting that they may have undergone a similar weathering process. In the end, to cope with inevitable airborne contamination, several measures were proposed for further research. Such measures will provide the necessary methodological assistance for accurate quantification of MP pollution in the field.
AB - Quality assurance and quality control (QA&QC) procedures are vital for ensuring data reliability, but little is known about the use of such procedures in reducing airborne microplastic (MP) contamination. To address this issue, we tried to determine the efficiency of two common methods (washing and ashing experimental glassware) for removing airborne MPs and identified airborne contamination during MP analytical procedure. The results showed the removal efficiencies of washing and ashing were an average of 88%–98% and 100%, respectively, indicating that both methods could eliminate most of the spiked airborne MPs with no significant difference noted between the two methods. Although rigorous measures were taken to prevent contamination from ambient air, trace amounts of airborne MPs were still detected, which is an issue that has not been adequately investigated in previous studies. All of the procedural contaminants detected in this study were fibrous. Approximately 88% of these fibers were cotton-like (cotton, cellulose, and cellophane) fibers, and 13% of them were plastic. Surprisingly, cotton-like fibers and MPs had a similar size distribution, suggesting that they may have undergone a similar weathering process. In the end, to cope with inevitable airborne contamination, several measures were proposed for further research. Such measures will provide the necessary methodological assistance for accurate quantification of MP pollution in the field.
KW - Airborne microplastics
KW - Contamination
KW - Methodology
KW - Quality assurance
KW - Quality control
KW - Removal
UR - https://www.scopus.com/pages/publications/85090364038
U2 - 10.1016/j.scitotenv.2020.142118
DO - 10.1016/j.scitotenv.2020.142118
M3 - 文章
C2 - 32911154
AN - SCOPUS:85090364038
SN - 0048-9697
VL - 754
JO - Science of the Total Environment
JF - Science of the Total Environment
M1 - 142118
ER -