TY - JOUR
T1 - Theory and development of biplanar active shim coils for a permanent NMR analyzer
AU - Xia, Tian
AU - Miao, Zhiying
AU - Chen, Shanshan
AU - Wang, Hongzhi
AU - Yao, Yefeng
N1 - Publisher Copyright:
© 2017 Xia et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2017/7
Y1 - 2017/7
N2 - The general expression for magnetic induction in the z axis direction is derived from magnetic scalar potential, and magnetic induction for biplanar shimming coils (BSCs) is also derived from magnetic vector potentials and Green functions, which simultaneously include Sin and Cos harmonic fields. The relationship between these expressions is discussed, and we show they are partially consistent. Magnetic induction generated Sin and Cos stream functions, which are presented and discussed, and we conclude that the type of stream function determines the type of harmonic field, and that BSCs can not only generate specific harmonic fields directly using Cos stream function, but also generate the rest of the harmonic fields through some specific operations. The detailed design process is presented in the form of a diagram. Subsequently, nine BSCs were calculated using the proposed method and applied to a low field NMR relaxation analyzer. The magnetic field homogeneity after shimming increases significantly, which verifies its practical value.
AB - The general expression for magnetic induction in the z axis direction is derived from magnetic scalar potential, and magnetic induction for biplanar shimming coils (BSCs) is also derived from magnetic vector potentials and Green functions, which simultaneously include Sin and Cos harmonic fields. The relationship between these expressions is discussed, and we show they are partially consistent. Magnetic induction generated Sin and Cos stream functions, which are presented and discussed, and we conclude that the type of stream function determines the type of harmonic field, and that BSCs can not only generate specific harmonic fields directly using Cos stream function, but also generate the rest of the harmonic fields through some specific operations. The detailed design process is presented in the form of a diagram. Subsequently, nine BSCs were calculated using the proposed method and applied to a low field NMR relaxation analyzer. The magnetic field homogeneity after shimming increases significantly, which verifies its practical value.
UR - https://www.scopus.com/pages/publications/85025159278
U2 - 10.1371/journal.pone.0181552
DO - 10.1371/journal.pone.0181552
M3 - 文章
C2 - 28742132
AN - SCOPUS:85025159278
SN - 1932-6203
VL - 12
JO - PLoS ONE
JF - PLoS ONE
IS - 7
M1 - e0181552
ER -