The TOF spectrometer for photoneutron measurement at SLEGS

  • Kai Jie Chen
  • , Long Xiang Liu
  • , Yue Zhang
  • , Zi Rui Hao
  • , Hang Hua Xu
  • , Qian Kun Sun
  • , Sheng Jin
  • , Yu Xuan Yang
  • , Zhen Wei Wang
  • , Zhi Cai Li
  • , Pu Jiao
  • , Meng Die Zhou
  • , Meng Ke Xu
  • , Xiang Fei Wang
  • , Yu Long Shen
  • , Gong Tao Fan
  • , Hong Wei Wang*
  • , Yu Gang Ma*
  • *Corresponding author for this work
  • ShanghaiTech University
  • Chinese Academy of Sciences
  • CAS - Shanghai Advanced Research Institute
  • University of Chinese Academy of Sciences
  • School of Physics
  • University of South China
  • Henan Normal University
  • Fudan University

Research output: Contribution to journal › Article › peer-review

Abstract

Above the neutron separation energy, photon absorption is dominated by the Giant Dipole Resonance (GDR), which is the dominant mechanism for incident γ-rays energies typically exceeding 10 MeV. This absorption leads to highly excited compound nuclei that decay predominantly through neutron emission, resulting in the formation of daughter nuclei. Subsequent de-excitation of these daughters via γ-rays cascades to low-lying states offers valuable insights into nuclear structure. The SLEGS Time-Of-Flight (TOF) spectrometer which consists of twenty neutron liquid Scintillators (EJ301), covering a total solid angle of 0.1126 sr - approximately 0.9% of the full 4π sphere and eight [Figure presented] γ-rays detectors, covering a total solid angle of 0.4054 sr - approximately 3.2% of the full 4π sphere, has been constructed and tested in both offline and online experiments. The experimental result shows that the total absolute γ-rays detection efficiency is 1.15%@1332 keV with an efficiency stability 5.8%, the total absolute neutron detection efficiency is 0.31%@2.13MeV with an efficiency stability 1.3%. The energy resolution for neutrons is approximately 8.5%@4 MeV. To evaluate the performance of the setup and validate the data analysis procedures, an online coincidence measurement of the reaction [Figure presented] was performed using approximately 13 MeV quasi-monochromatic γ rays from the SLEGS beamline. The measurement revealed features consistent with a high level density and the presence of multiple rotational bands in [Figure presented], while also verifying the stable operation of the spectrometer.

Original languageEnglish
Article number171174
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume1084
DOIs
StatePublished - Apr 2026
Externally publishedYes

Keywords

  • GDR
  • Photo-neutron reaction
  • SLEGS
  • TOF spectrometer
  • γ rays

Fingerprint