TY - JOUR
T1 - The influence of different ionic concentration in cell physiological solution on temperature measurement by near infrared
AU - Zheng, Yu
AU - Chen, Xiong
AU - Zhou, Mei
AU - Wang, Meng Jun
AU - Wang, Jin Hai
AU - Li, Gang
AU - Cui, Jun
N1 - Publisher Copyright:
© 2015, Science Press. All right reserved.
PY - 2015/10/1
Y1 - 2015/10/1
N2 - It is important to real-timely monitor and control the temperature of cell physiological solution in patch clamp experiments, which can eliminate the uncertainty due to temperature and improve the measurement accuracy. This paper studies the influence of different ions at different concentrations in the physiological solution on precision of a temperature model by using near infrared spectroscopy and chemometrics method. Firstly, we prepared twelve sample solutions respectively with the solutes of CaCl2, KCl and NaCl at four kinds of concentrations, and collected the spectra of different solutions at the setting temperature range 20~40℃, the range of the spectra is 9 615~5 714 cm-1. Then we divided the spectra of each solution at different temperatures into two parts (a training set and a prediction set) by three methods. Interval partial least squares method was used to select an effective wavelength range and develop calibration models between the spectra in the selected range and temperature velues. The experimental results show that RMSEP of CaCl2 solution with 0.25 g·mL-1 is maximum, the result of the three tests are 0.386 3, 0.303 7 and 0.337 2℃, RMSEP of NaCl with 0.005 g·mL-1 solution is minimum, the result of the three tests are 0.220 8, 0.155 3 and 0.145 2℃. The experimental results indicate that Ca2+ has the greatest influence on the accuracy of the temperature model of the cell physiological solution, then K+, and Na+ has the least influence. And with the ionic concentration increasing, the model accuracy decreases. Therefore, when we build the temperature model of cell physiological solution, it is necessary to change the proportion of the three kinds of main ions in cell physiological solution reasonably in order to correct the effects of different ionic concentrations in physiological solution and improve the accuracy of temperature measurements by near infrared spectroscopy.
AB - It is important to real-timely monitor and control the temperature of cell physiological solution in patch clamp experiments, which can eliminate the uncertainty due to temperature and improve the measurement accuracy. This paper studies the influence of different ions at different concentrations in the physiological solution on precision of a temperature model by using near infrared spectroscopy and chemometrics method. Firstly, we prepared twelve sample solutions respectively with the solutes of CaCl2, KCl and NaCl at four kinds of concentrations, and collected the spectra of different solutions at the setting temperature range 20~40℃, the range of the spectra is 9 615~5 714 cm-1. Then we divided the spectra of each solution at different temperatures into two parts (a training set and a prediction set) by three methods. Interval partial least squares method was used to select an effective wavelength range and develop calibration models between the spectra in the selected range and temperature velues. The experimental results show that RMSEP of CaCl2 solution with 0.25 g·mL-1 is maximum, the result of the three tests are 0.386 3, 0.303 7 and 0.337 2℃, RMSEP of NaCl with 0.005 g·mL-1 solution is minimum, the result of the three tests are 0.220 8, 0.155 3 and 0.145 2℃. The experimental results indicate that Ca2+ has the greatest influence on the accuracy of the temperature model of the cell physiological solution, then K+, and Na+ has the least influence. And with the ionic concentration increasing, the model accuracy decreases. Therefore, when we build the temperature model of cell physiological solution, it is necessary to change the proportion of the three kinds of main ions in cell physiological solution reasonably in order to correct the effects of different ionic concentrations in physiological solution and improve the accuracy of temperature measurements by near infrared spectroscopy.
KW - Cell physiological solution
KW - Interval partial least squares
KW - Ionic concentration
KW - Near infrared spectroscopy
KW - Temperature
UR - https://www.scopus.com/pages/publications/84952774658
U2 - 10.3964/j.issn.1000-0593(2015)10-2718-05
DO - 10.3964/j.issn.1000-0593(2015)10-2718-05
M3 - 文章
C2 - 26904806
AN - SCOPUS:84952774658
SN - 1000-0593
VL - 35
SP - 2718
EP - 2722
JO - Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis
JF - Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis
IS - 10
ER -