TY - JOUR
T1 - Systematic evaluation and optimization of high-performance liquid chromatography separation of polyoxins
AU - Li, Zhidong
AU - Fu, Qing
AU - Li, Shiliang
AU - Jin, Yu
AU - Liang, Xinmiao
N1 - Publisher Copyright:
© 2020 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
PY - 2020/8/1
Y1 - 2020/8/1
N2 - The chromatographic behavior of a kind of nucleoside peptides, polyoxins, was investigated in this study. Molecular simulation technique was used to elucidate the temperature-dependent peak sharpening of polyoxins. There was a relatively small energy barrier between the global minimum conformer and the local minimum conformer of polyoxin A and the high temperature helped to quickly cross the energy barrier and accelerate the conformational transformation for getting the global minimum, so that stationary phase could not identify these two conformations and presented a sharp peak. Two kinds of mixed-mode columns, strong cation exchange or strong anion exchange ligands bonded with C18 (C18SCX and C18SAX) were used to improve separation selectivity of four polyoxins (A, K, F, H). The electrostatic attraction was necessary to increase the retention to ensure that the alkyl chain can give better play to its hydrophobic effect. Therefore, four polyoxins were well separated on C18SCX at pH 2 and they were also well separated on C18SAX at pH 7. In the small-scale purification of polyoxins, the sample loading of the C18SCX was five times than that of the C18SAX and the purity of the collected four polyoxins was all over 90%.
AB - The chromatographic behavior of a kind of nucleoside peptides, polyoxins, was investigated in this study. Molecular simulation technique was used to elucidate the temperature-dependent peak sharpening of polyoxins. There was a relatively small energy barrier between the global minimum conformer and the local minimum conformer of polyoxin A and the high temperature helped to quickly cross the energy barrier and accelerate the conformational transformation for getting the global minimum, so that stationary phase could not identify these two conformations and presented a sharp peak. Two kinds of mixed-mode columns, strong cation exchange or strong anion exchange ligands bonded with C18 (C18SCX and C18SAX) were used to improve separation selectivity of four polyoxins (A, K, F, H). The electrostatic attraction was necessary to increase the retention to ensure that the alkyl chain can give better play to its hydrophobic effect. Therefore, four polyoxins were well separated on C18SCX at pH 2 and they were also well separated on C18SAX at pH 7. In the small-scale purification of polyoxins, the sample loading of the C18SCX was five times than that of the C18SAX and the purity of the collected four polyoxins was all over 90%.
KW - high-performance liquid chromatography
KW - mixed-mode stationary phase
KW - molecular simulation
KW - peptides
KW - polyoxins
UR - https://www.scopus.com/pages/publications/85087772770
U2 - 10.1002/jssc.202000269
DO - 10.1002/jssc.202000269
M3 - 文章
C2 - 32453909
AN - SCOPUS:85087772770
SN - 1615-9306
VL - 43
SP - 3006
EP - 3016
JO - Journal of Separation Science
JF - Journal of Separation Science
IS - 15
ER -