TY - JOUR
T1 - Size-tunable Pt nanoparticles assembled on functionalized ordered mesoporous carbon for the simultaneous and on-line detection of glucose and L-lactate in brain microdialysate
AU - Yu, Yanyan
AU - Yang, Yan
AU - Gu, Hui
AU - Zhou, Tianshu
AU - Shi, Guoyue
PY - 2013/3/15
Y1 - 2013/3/15
N2 - This study presents a facile electrochemical method for simultaneous and selective on-line detection of glucose and L-lactate in the striatum of anesthetic rats through the integration of selective electrochemical detection with in vivo microdialysis system. A positively-charged polyelectrolyte, (diallyldimethylammonium chloride) (PDDA), was attached onto carbon mesoporous material (CMM) through non-covalent interaction, which provided an ideal environment for the assembling and dispersion of nanoparticle electrocatalysts. Platinum nanoparticles with wide loadings from 5 to 50. wt% were successfully self-assembled on PDDA-functionalized CMM via electrostatic interaction. TEM results showed that with the increase in the Pt loadings, both the size and interconnectivity between particles increased, with particle sizes ranging from 3.2±0.4 to 6.8±1.4. nm. Moreover, the electrocatalytic activities of the as-prepared six Pt/PDDA-CMM hybrid nanocomposites were also observed to show an inverted-V-shaped profile as a function of loading amount of Pt NPs. Integrated with glucose oxidase (GOx), L-lactate oxidase (LOD) and the in vivo microdialysis system, the constructed dual oxidase/Pt/PDDA-CMM/Nafion biosensors were successfully applied for the simultaneous and on-line detection of glucose and L-lactate. After post-calibration, the basal level of glucose and L-lactate in the striatum of anesthetic rats was calculated to be 0.27±0.03 and 0.71±0.05. mM (mean ±s.d., n=3), respectively. What is more important, the dual oxidase biosensors almost suffered from little cross-talk, which is characteristic of an excellent sensor with high performance. This property, along with the good linearity and a high stability substantially enables this method promising application in physiology and pathology.
AB - This study presents a facile electrochemical method for simultaneous and selective on-line detection of glucose and L-lactate in the striatum of anesthetic rats through the integration of selective electrochemical detection with in vivo microdialysis system. A positively-charged polyelectrolyte, (diallyldimethylammonium chloride) (PDDA), was attached onto carbon mesoporous material (CMM) through non-covalent interaction, which provided an ideal environment for the assembling and dispersion of nanoparticle electrocatalysts. Platinum nanoparticles with wide loadings from 5 to 50. wt% were successfully self-assembled on PDDA-functionalized CMM via electrostatic interaction. TEM results showed that with the increase in the Pt loadings, both the size and interconnectivity between particles increased, with particle sizes ranging from 3.2±0.4 to 6.8±1.4. nm. Moreover, the electrocatalytic activities of the as-prepared six Pt/PDDA-CMM hybrid nanocomposites were also observed to show an inverted-V-shaped profile as a function of loading amount of Pt NPs. Integrated with glucose oxidase (GOx), L-lactate oxidase (LOD) and the in vivo microdialysis system, the constructed dual oxidase/Pt/PDDA-CMM/Nafion biosensors were successfully applied for the simultaneous and on-line detection of glucose and L-lactate. After post-calibration, the basal level of glucose and L-lactate in the striatum of anesthetic rats was calculated to be 0.27±0.03 and 0.71±0.05. mM (mean ±s.d., n=3), respectively. What is more important, the dual oxidase biosensors almost suffered from little cross-talk, which is characteristic of an excellent sensor with high performance. This property, along with the good linearity and a high stability substantially enables this method promising application in physiology and pathology.
KW - Glucose
KW - In vivo
KW - L-lactate
KW - On-line microdialysis system
KW - Pt/PDDA-CMM hybrid nanocomposite
UR - https://www.scopus.com/pages/publications/84870818255
U2 - 10.1016/j.bios.2012.09.055
DO - 10.1016/j.bios.2012.09.055
M3 - 文章
C2 - 23089326
AN - SCOPUS:84870818255
SN - 0956-5663
VL - 41
SP - 511
EP - 518
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
IS - 1
ER -