TY - JOUR
T1 - Simultaneous determination of monoamines in rat brain with Pt/MWCNTs@Pdop hybrid nanocomposite using capillary electrophoresis- amperometric detection
AU - Liu, Xiaoqian
AU - Yu, Yanyan
AU - Gu, Hui
AU - Zhou, Tianshu
AU - Wang, Lili
AU - Mei, Bing
AU - Shi, Guoyue
PY - 2013/3
Y1 - 2013/3
N2 - In this article, polydopamine (Pdop) functionalized multiwalled carbon nanotubes (MWCNTs@Pdop) were firstly synthesized and employed as the template for the dispersion of Pt nanoparticles to form Pt/MWCNTs@Pdop hybrid nanocomposite. The characterizations of the Pt/MWCNTs@Pdop were investigated by SEM, transmission electron microscopy, x-ray diffraction, and voltammetry. Based upon the Pt/MWCNTs@Pdop nanocomposite, a modified carbon disk electrode was fabricated and successfully applied to the simultaneous detection of four important monoamines, including dopamine, epinephrine, norepinephrine, and serotonin, using capillary electrophoresis-amperometric detection system. Compared with the bare electrode, the four analytes at the Pt/MWCNTs@Pdop electrode exhibited higher sensitivity, broad linear responses from 0.5 to 1.0 × 102 nmol/L. The detection limits (S/N = 3) were lower than 9.2 × 10-10 mol/L. More importantly, the effect of noise exposure on monoamines (MAs) in hippocampus and hypothalamus was investigated for the first time. Compared with the control group, the levels of the MAs all varied to different extents after rats receiving the same noise stimulation. The results showed that the proposed method could be applied to the determination of low levels of MAs in biological samples and screening the target molecules for the diagnosis and treatment of various related diseases.
AB - In this article, polydopamine (Pdop) functionalized multiwalled carbon nanotubes (MWCNTs@Pdop) were firstly synthesized and employed as the template for the dispersion of Pt nanoparticles to form Pt/MWCNTs@Pdop hybrid nanocomposite. The characterizations of the Pt/MWCNTs@Pdop were investigated by SEM, transmission electron microscopy, x-ray diffraction, and voltammetry. Based upon the Pt/MWCNTs@Pdop nanocomposite, a modified carbon disk electrode was fabricated and successfully applied to the simultaneous detection of four important monoamines, including dopamine, epinephrine, norepinephrine, and serotonin, using capillary electrophoresis-amperometric detection system. Compared with the bare electrode, the four analytes at the Pt/MWCNTs@Pdop electrode exhibited higher sensitivity, broad linear responses from 0.5 to 1.0 × 102 nmol/L. The detection limits (S/N = 3) were lower than 9.2 × 10-10 mol/L. More importantly, the effect of noise exposure on monoamines (MAs) in hippocampus and hypothalamus was investigated for the first time. Compared with the control group, the levels of the MAs all varied to different extents after rats receiving the same noise stimulation. The results showed that the proposed method could be applied to the determination of low levels of MAs in biological samples and screening the target molecules for the diagnosis and treatment of various related diseases.
KW - Amperometric detection
KW - Capillary electrophoresis
KW - Monoamines
KW - Pt/MWCNTs@Pdop hybrid nanocomposite
UR - https://www.scopus.com/pages/publications/84875000366
U2 - 10.1002/elps.201200071
DO - 10.1002/elps.201200071
M3 - 文章
C2 - 23335195
AN - SCOPUS:84875000366
SN - 0173-0835
VL - 34
SP - 935
EP - 943
JO - Electrophoresis
JF - Electrophoresis
IS - 6
ER -