TY - JOUR
T1 - Simultaneous determination of biogenic monoamines in rat brain dialysates using capillary high-performance liquid chromatography with photoluminescence following electron transfer
AU - Jung, Moon Chul
AU - Shi, Guoyue
AU - Borland, Laura
AU - Michael, Adrian C.
AU - Weber, Stephen G.
PY - 2006/3/15
Y1 - 2006/3/15
N2 - Simultaneous determination of biogenic monoamines such as dopamine, serotonin, and 3-methoxytyramine in brain is important in understanding neurotransmitter activity. This study presents a sensitive determination of biogenic monoamines in rat brain striatum microdialysates using capillary high-performance liquid chromatography with the photoluminescence following electron-transfer detection technique. Separation conditions were optimized by changing the concentration of an ion-interaction agent and the percentage of an organic modifier. The high concentration of ion-interaction agent enabled the amines as a class to be separated from interfering acids, but also made the separation very long. To shorten the separation time, 10% (v/v) acetonitrile was used as the organic modifier. Eight Chromatographic runs during a 3-h period were analyzed in terms of retention times, peak heights, and peak widths. Chromatograms are very reproducible, with less than 1% changes in peak height over 3 h. Typical concentration detection limits at the optimum separation conditions were less than 100 pM for metabolic acids and ∼200 pM for monoamines. The injection volume of the sample was 500 nL. Thus, the mass detection limits were less than 50 amol for metabolic acids and ∼100 amol for monoamines. Typical separation time was less than 10 min. To validate the technique, the separation method was applied to the observation of drug-induced changes of monoamine concentrations in rat brain microdialysis samples. Local perfusion of tetrodotoxin, a sodium channel blocker, into the striatum of an anesthetized rat decreased dopamine, 3-methoxytyramine, and serotonin concentrations in dialysates. Successive monitoring of striatal dialysates at a temporal resolution of 7.7 min showed that the injection of nomifensine transiently increased dopamine and 3-methoxytyramine concentrations in rat brain dialysate.
AB - Simultaneous determination of biogenic monoamines such as dopamine, serotonin, and 3-methoxytyramine in brain is important in understanding neurotransmitter activity. This study presents a sensitive determination of biogenic monoamines in rat brain striatum microdialysates using capillary high-performance liquid chromatography with the photoluminescence following electron-transfer detection technique. Separation conditions were optimized by changing the concentration of an ion-interaction agent and the percentage of an organic modifier. The high concentration of ion-interaction agent enabled the amines as a class to be separated from interfering acids, but also made the separation very long. To shorten the separation time, 10% (v/v) acetonitrile was used as the organic modifier. Eight Chromatographic runs during a 3-h period were analyzed in terms of retention times, peak heights, and peak widths. Chromatograms are very reproducible, with less than 1% changes in peak height over 3 h. Typical concentration detection limits at the optimum separation conditions were less than 100 pM for metabolic acids and ∼200 pM for monoamines. The injection volume of the sample was 500 nL. Thus, the mass detection limits were less than 50 amol for metabolic acids and ∼100 amol for monoamines. Typical separation time was less than 10 min. To validate the technique, the separation method was applied to the observation of drug-induced changes of monoamine concentrations in rat brain microdialysis samples. Local perfusion of tetrodotoxin, a sodium channel blocker, into the striatum of an anesthetized rat decreased dopamine, 3-methoxytyramine, and serotonin concentrations in dialysates. Successive monitoring of striatal dialysates at a temporal resolution of 7.7 min showed that the injection of nomifensine transiently increased dopamine and 3-methoxytyramine concentrations in rat brain dialysate.
UR - https://www.scopus.com/pages/publications/33645234138
U2 - 10.1021/ac051183g
DO - 10.1021/ac051183g
M3 - 文章
C2 - 16536408
AN - SCOPUS:33645234138
SN - 0003-2700
VL - 78
SP - 1755
EP - 1760
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 6
ER -