TY - JOUR
T1 - Sensitive determination of nine anticoagulant rodenticides in blood by high resolution mass spectrometry with supported liquid extraction pretreatment
AU - Gao, Xue
AU - Li, Hongge
AU - Li, Hui
AU - Dong, Shuai
AU - Chu, Junhao
AU - Guo, Hao
AU - Zhao, Qingbiao
N1 - Publisher Copyright:
© 2018
PY - 2018/11
Y1 - 2018/11
N2 - Anticoagulant rodenticides (ARs) have been widely used for controlling rodents in agriculture and households. It often occurs that non-target animals are poisoned by ARs. Also, the abuse of ARs has been often encountered in poisoning and suicide cases. Herein we report the determination of nine commonly used ARs by high resolution mass spectrometry (HRMS) with supported liquid extraction (SLE) pretreatment. The factors affecting SLE (elution solvents and pH values) were systematically tested and optimized. The application of parallel reaction monitoring (PRM) mode led to the highest sensitivity obtained for these compounds, with LODs ranging for 0.006–0.02 ng/mL. Reasonable extraction recoveries for all the analytes were obtained ranging in 73.9%–110.7%. Good precision was achieved for the spiked blood samples, with intra-day RSD ranging in 5.0%–9.2% and inter-day RSD ranging in 6.3%–10.5%. The values of ME ranged in 82.9%–103.2% for QC sample, which are reasonable. The application of HRMS in PRM mode also resulted in high selectivity. The method was applied to the detection and quantification of ARs in blood samples from real forensic cases. This methodology possesses high potential for determination of rodenticides in clinical and forensic cases.
AB - Anticoagulant rodenticides (ARs) have been widely used for controlling rodents in agriculture and households. It often occurs that non-target animals are poisoned by ARs. Also, the abuse of ARs has been often encountered in poisoning and suicide cases. Herein we report the determination of nine commonly used ARs by high resolution mass spectrometry (HRMS) with supported liquid extraction (SLE) pretreatment. The factors affecting SLE (elution solvents and pH values) were systematically tested and optimized. The application of parallel reaction monitoring (PRM) mode led to the highest sensitivity obtained for these compounds, with LODs ranging for 0.006–0.02 ng/mL. Reasonable extraction recoveries for all the analytes were obtained ranging in 73.9%–110.7%. Good precision was achieved for the spiked blood samples, with intra-day RSD ranging in 5.0%–9.2% and inter-day RSD ranging in 6.3%–10.5%. The values of ME ranged in 82.9%–103.2% for QC sample, which are reasonable. The application of HRMS in PRM mode also resulted in high selectivity. The method was applied to the detection and quantification of ARs in blood samples from real forensic cases. This methodology possesses high potential for determination of rodenticides in clinical and forensic cases.
KW - Anticoagulant rodenticides
KW - High resolution mass spectrometry
KW - Parallel reaction monitoring
KW - Supported liquid extraction
KW - UHPLC
UR - https://www.scopus.com/pages/publications/85053854360
U2 - 10.1016/j.forsciint.2018.09.009
DO - 10.1016/j.forsciint.2018.09.009
M3 - 文章
C2 - 30269045
AN - SCOPUS:85053854360
SN - 0379-0738
VL - 292
SP - 39
EP - 44
JO - Forensic Science International
JF - Forensic Science International
ER -