Sensitive determination of neodymium isotope in seawater by multi-collector inductively coupled plasma mass spectrometry with ultrasound nebulization-dielectric barrier discharge vapor generation as sample introduction

  • Dongyong Li
  • , Guanghao Cui
  • , Shanshan Chen
  • , Yifan Qiao
  • , Qian Liu
  • , Jing Zhang
  • , Qian He*
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

In this work, a highly sensitive Nd isotopic analysis method by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) with ultrasound nebulization-dielectric barrier discharge (UNDBD) vapor generation as sample introduction is developed. The sensitivities of Nd isotopes determined by UNDBD are enhanced about 4.5 fold and 1.5 fold compared to conventional wet plasma and dry plasma, respectively, attributed to the generation of volatile Nd species during the dielectric barrier discharge (DBD) induced vapor generation process. Fractionation of Nd isotopes in UNDBD exhibits a mass-dependent characteristic, enabling successful correction of the 143Nd/144Nd ratio using the 146Nd/144Nd ratio with an exponential law. The minimum Nd concentration and volume required per analysis by UNDBD-MC-ICP-MS can be as low as 0.5 μg L−1 and 600 μL, thereby minimizing the sampling volume for Nd isotopic analysis in open seawater to 0.7 L. Interferences from residual major ions in seawater, present at mg L−1 level after pretreatment, are found to be negligible for Nd isotopic analysis by UNDBD-MC-ICP-MS. The long-term external precision (2RSD) for 143Nd/144Nd with 1 μg L−1 of Nd using this method is calculated as 64 ppm. The accuracy of 143Nd/144Nd determined by this method has been successfully validated by Nd isotopic standard solutions of GSB 04-3258-2015 and GBW04440. The Nd isotopic ratios determined in several seawater samples by UNDBD are in agreement with results obtained by the dry plasma method. UNDBD demonstrates both higher sensitivity and precision for Nd isotopic analysis compared to wet plasma and dry plasma sample introduction methods, making it more suitable for analyzing open seawater samples with low Nd concentrations and less sampling volume.

Original languageEnglish
Pages (from-to)2395-2401
Number of pages7
JournalJournal of Analytical Atomic Spectrometry
Volume39
Issue number10
DOIs
StatePublished - 24 Jul 2024