TY - JOUR
T1 - Optimization of a compact on-site stormwater runoff treatment system
T2 - Process performance and reactor design
AU - Qin, Yangjie
AU - Zhou, Chuanting
AU - Yu, Siqi
AU - Pang, Hongjian
AU - Guo, Jiaming
AU - Wei, Jun
AU - Wang, Libing
AU - Xing, Yunxin
AU - An, Ying
AU - Zhou, Zhen
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/2
Y1 - 2023/2
N2 - Stormwater runoff has become a major anthropogenic urban pollution source that threatens water quality. In this study, coagulation-sedimentation, and ammonium ion exchange and regeneration (AIR) modules were coupled as a CAIR system to efficiently treat stormwater runoff. In the coagulation module, 99.3%, 91.7%, and 97.0% of turbidity, total phosphorus, and chemical oxygen demand could be removed at an optimized poly-aluminum ferric chloride dosage of 30 mg/L, and the continuous experiment confirmed that the full load mode was more suitable for its rapid start-up. In the AIR module, dynamic ammonium removal indicated that the breakthrough time decreased with the rising initial concentration and superficial velocity. The Modified Dose Response (MDR) model described the ammonium exchange behavior better than the Thomas and the Bohart-Adams models. Then, a design flow of the ion exchange reactor was constructed by correlating constants in the MDR model with engineering parameters, and the ion exchange reactor was designed for continuous operation of the CAIR system. The average concentrations of chemical oxygen demand, total phosphorus, ammonium nitrogen, and total nitrogen in the effluent of the CAIR system were 7.22 ± 2.26, 0.17 ± 0.05, 1.49 ± 0.01, and 1.62 ± 0.02 mg/L, respectively. The almost unchanged exchange capacity and physicochemical properties after the multicycle operation confirmed the durability of zeolite for ion exchange. Techno-economic analysis suggested that the CAIR system is practically promising for stormwater management with efficient pollutants removal, small footprint, and acceptable operating cost.
AB - Stormwater runoff has become a major anthropogenic urban pollution source that threatens water quality. In this study, coagulation-sedimentation, and ammonium ion exchange and regeneration (AIR) modules were coupled as a CAIR system to efficiently treat stormwater runoff. In the coagulation module, 99.3%, 91.7%, and 97.0% of turbidity, total phosphorus, and chemical oxygen demand could be removed at an optimized poly-aluminum ferric chloride dosage of 30 mg/L, and the continuous experiment confirmed that the full load mode was more suitable for its rapid start-up. In the AIR module, dynamic ammonium removal indicated that the breakthrough time decreased with the rising initial concentration and superficial velocity. The Modified Dose Response (MDR) model described the ammonium exchange behavior better than the Thomas and the Bohart-Adams models. Then, a design flow of the ion exchange reactor was constructed by correlating constants in the MDR model with engineering parameters, and the ion exchange reactor was designed for continuous operation of the CAIR system. The average concentrations of chemical oxygen demand, total phosphorus, ammonium nitrogen, and total nitrogen in the effluent of the CAIR system were 7.22 ± 2.26, 0.17 ± 0.05, 1.49 ± 0.01, and 1.62 ± 0.02 mg/L, respectively. The almost unchanged exchange capacity and physicochemical properties after the multicycle operation confirmed the durability of zeolite for ion exchange. Techno-economic analysis suggested that the CAIR system is practically promising for stormwater management with efficient pollutants removal, small footprint, and acceptable operating cost.
KW - Breakthrough curve
KW - Coagulation
KW - Column model
KW - Ion exchange
KW - Stormwater runoff
UR - https://www.scopus.com/pages/publications/85146005153
U2 - 10.1016/j.chemosphere.2023.137767
DO - 10.1016/j.chemosphere.2023.137767
M3 - 文章
C2 - 36610516
AN - SCOPUS:85146005153
SN - 0045-6535
VL - 315
JO - Chemosphere
JF - Chemosphere
M1 - 137767
ER -