Skip to main navigation Skip to search Skip to main content

New method of measuring arterial oxygen saturation

  • Gang Li
  • , Lei Bao
  • , Mei Zhou
  • , Ling Lin
  • , Rui Liu
  • , Chun Jie Zhao*
  • *Corresponding author for this work
  • Tianjin University
  • Tianjin Union Medical Center
  • Health Physical Examination Center

Research output: Contribution to journalArticlepeer-review

Abstract

The traditional method of measuring arterial oxygen saturation is that R value, the ratio of alternating component of the logarithmic photoplethysmography, is firstly computed and then the linear regression model is established by experiment. The R value computation is a dimension reduction process based on Lambert-beer law, which aims at eliminating the influence of optical path andminimizing the impact of individual differences. When taking scattering into consideration, the dimension reduction process loses information, introduces the system error and limits the precision of measurement. In order to reduce the measurement error resulting from the scattering effects, this paper presents a new method that the peak and valley values of dual-wavelength logarithmic photoplethysmography waves are used as the independent variables to develop a linear regression model to predict the arterial oxygen saturation. During the experiment, the in-vivo measurements were carried out on 23 healthy volunteer and 133 samples of photoplethysmography waves and the reference value of oxygen saturation were recorded. To compare the predictive performance between the new method and the R value method, 90 samples were randomly selected as modeling sets and the remaining 43 samples were used as prediction sets. Random selection of modeling sets and prediction are executed 10 times. The average related coefficients of the prediction sets of the new method and the R value method are 0.890 6 and 0.846 8, and the average root mean square errors are 0.889 6% and 1.037 3% respectively. Results indicate that the performance of the new method is better than the one of the R value method, and the predictivemodel based on 4 parameters can improve the stability and accuracy of measurement. And the new method has guiding significance to the measurement of human body's blood physiological information based on limited wavelength spectrum data.

Original languageEnglish
Pages (from-to)196-200
Number of pages5
JournalGuang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis
Volume36
Issue number1
DOIs
StatePublished - 1 Jan 2016

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Noninvasive measurements
  • Oxygen saturation
  • Partial least squares
  • Photoplethysmography wave

Fingerprint

Dive into the research topics of 'New method of measuring arterial oxygen saturation'. Together they form a unique fingerprint.

Cite this