TY - JOUR
T1 - Multi-channel in vivo recording technique
T2 - microdrive array fabrication and electrode implantation in mice
AU - Ma, Xiao Yu
AU - Zhang, Yi Yao
AU - Wang, Li Na
AU - Lin, Long Nian
PY - 2013/12/25
Y1 - 2013/12/25
N2 - Here we describe and illustrate our methods for multi-channel in vivo recording in mice, including the fabrication of the microdrive array and the surgical procedure for implanting electrodes. The multi-channel microdrive is fabricated from printed circuit board base, screws, nuts and clamping screws. Rotation of the screw drives both the nut and the attached electrodes to move forward simultaneously. Each full turn of the screw corresponds to 280 µm in depth penetration. The recording electrodes are self-made tetrodes consisting 4 wires (13 µm in diameter). The major steps of headstage fabrication include: tetrode making, microdrive construction, headstage assembling and tetrode plating. The finished headstage is suitable for multi-channel recording in freely moving rodents with the modest weight and the adjustable number of recording electrodes. Additionally, the recording site is allowed to be manipulated after implantation at any time. In the latter part of this paper, we introduce the procedure of the implant surgery to record in bilateral hippocampus in mice. Using these headstages, we simultaneously recorded population activity in bilateral CA1 in freely behaving mice.
AB - Here we describe and illustrate our methods for multi-channel in vivo recording in mice, including the fabrication of the microdrive array and the surgical procedure for implanting electrodes. The multi-channel microdrive is fabricated from printed circuit board base, screws, nuts and clamping screws. Rotation of the screw drives both the nut and the attached electrodes to move forward simultaneously. Each full turn of the screw corresponds to 280 µm in depth penetration. The recording electrodes are self-made tetrodes consisting 4 wires (13 µm in diameter). The major steps of headstage fabrication include: tetrode making, microdrive construction, headstage assembling and tetrode plating. The finished headstage is suitable for multi-channel recording in freely moving rodents with the modest weight and the adjustable number of recording electrodes. Additionally, the recording site is allowed to be manipulated after implantation at any time. In the latter part of this paper, we introduce the procedure of the implant surgery to record in bilateral hippocampus in mice. Using these headstages, we simultaneously recorded population activity in bilateral CA1 in freely behaving mice.
UR - https://www.scopus.com/pages/publications/84929501776
M3 - 文章
C2 - 24343722
AN - SCOPUS:84929501776
SN - 0371-0874
VL - 65
SP - 637
EP - 646
JO - Acta Physiologica Sinica
JF - Acta Physiologica Sinica
IS - 6
ER -