TY - JOUR
T1 - Molecularly imprinted sensor based on electropolmerized poly(o-phenylenediamine) membranes at reduced graphene oxide modified electrode for imidacloprid determination
AU - Kong, Lei
AU - Jiang, Xiaoying
AU - Zeng, Yanbo
AU - Zhou, Tianshu
AU - Shi, Guoyue
PY - 2013
Y1 - 2013
N2 - In this paper, a novel electrochemical sensor based on imprinted poly(o-phenylenediamine) (PoPD) membranes at reduced graphene oxide (RGO) modified electrode for selective and sensitive detection of imidacloprid was fabricated. RGO was dropped onto the surface of the glassy carbon electrode (GCE) to amplify the electrocatalytic activity. The imprinted PoPD membranes were then synthesized onto RGO surface by electropolymerization using oPD as the monomer and imidacloprid as the template. The surface morphology was characterized by scanning electron microscopy (SEM). The feature of the imprinted electrode was performed by cyclic voltammetry (CV) and linear sweep voltammetry (LSV). The imprinted PoPD-RGO sensor exhibited good selectivity toward imidacloprid in comparison with other similar interferents. Under the optimal experimental conditions, the current response of the imprinted PoPD-RGO sensor was linear to the imidacloprid concentration in the range of 7.5 × 10-7 to 7.0 × 10-5 M with a detection limit of 4.0 × 10-7 M (S/N = 3). The imprinted electrochemical sensor was successfully employed for the selective determination of imidacloprid in real samples.
AB - In this paper, a novel electrochemical sensor based on imprinted poly(o-phenylenediamine) (PoPD) membranes at reduced graphene oxide (RGO) modified electrode for selective and sensitive detection of imidacloprid was fabricated. RGO was dropped onto the surface of the glassy carbon electrode (GCE) to amplify the electrocatalytic activity. The imprinted PoPD membranes were then synthesized onto RGO surface by electropolymerization using oPD as the monomer and imidacloprid as the template. The surface morphology was characterized by scanning electron microscopy (SEM). The feature of the imprinted electrode was performed by cyclic voltammetry (CV) and linear sweep voltammetry (LSV). The imprinted PoPD-RGO sensor exhibited good selectivity toward imidacloprid in comparison with other similar interferents. Under the optimal experimental conditions, the current response of the imprinted PoPD-RGO sensor was linear to the imidacloprid concentration in the range of 7.5 × 10-7 to 7.0 × 10-5 M with a detection limit of 4.0 × 10-7 M (S/N = 3). The imprinted electrochemical sensor was successfully employed for the selective determination of imidacloprid in real samples.
KW - Electrochemical sensor
KW - Electropolymerization
KW - Imidacloprid
KW - Imprinted poly(o-phenylenediamine) membranes
KW - Reduced graphene oxide
UR - https://www.scopus.com/pages/publications/84878893105
U2 - 10.1016/j.snb.2013.05.033
DO - 10.1016/j.snb.2013.05.033
M3 - 文章
AN - SCOPUS:84878893105
SN - 0925-4005
VL - 185
SP - 424
EP - 431
JO - Sensors and Actuators B: Chemical
JF - Sensors and Actuators B: Chemical
ER -