Abstract
Aiming to achieve important parameters of the electron density and plasma current density profile, a multi-channel far-infrared (FIR) laser Polarimeter/Interferometer is being developed for HL-3 tokamak by using the formic-acid laser source (HCOOH, λ=432.5 μm). All the 13 probing channels were distributed in two columns, including eight horizontally-viewing channels and five oblique channels. The stainless steel support tower (7.0 m high) was specially designed, and itself novel structure allowed us to arrange the light-paths of horizontal channels and oblique channels on two sides, respectively. Copper corner-cube-reflector (CCR) was mounted in the vacuum vessel to retrace the incident wave. In 2023, multi-channel line-integral electron densities were successfully derived by the interferometric measurement, with a time resolution of 1.0μs, line-integral density resolution of ∼5.0 × 1016/cm2. Right now, the interferometer system is being upgraded to three-wave based Polarimeter/Interferometer, which is able to simultaneously measure the electron density and Faraday rotation angle.
| Original language | English |
|---|---|
| Article number | 114489 |
| Journal | Fusion Engineering and Design |
| Volume | 204 |
| DOIs | |
| State | Published - Jul 2024 |
Keywords
- Electron density
- Faraday rotation angle
- Fir laser
- HL-3 tokamak
- Polarimeter/Interferometer
Fingerprint
Dive into the research topics of 'Mechanical and optical design of the FIR laser Polarimeter/Interferometer on the HL-3 tokamak'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver