TY - JOUR
T1 - Low-repetition-rate all-fiber integrated optical parametric oscillator for coherent anti-Stokes Raman spectroscopy
AU - Yang, Kangwen
AU - Zheng, Shikai
AU - Wu, Yuxing
AU - Ye, Pengbo
AU - Huang, Kun
AU - Hao, Qiang
AU - Zeng, Heping
N1 - Publisher Copyright:
© 2018 Optical Society of America.
PY - 2018/6/25
Y1 - 2018/6/25
N2 - All-fiber optical parametric oscillator (OPO), offering advantages like robustness, compactness and low lost, has attracted intense interest in coherent anti-Stokes Raman scattering spectroscopy. In typical fiber-based OPO configurations, detrimental nonlinear effects due to intense pump field in fiber coupling devices would inevitably degrade the spectral purity and conversion efficiency, especially when the OPO operated at low repetition rates. Here we demonstrated a new OPO design by placing the main amplifier inside the cavity, where the amplified pump pulses were directly coupled into the nonlinear fiber. Consequently, lower threshold, higher output power and narrower spectrum were obtained. In particular, effective suppression of spectral noise was experimentally observed, resulting in threshold reductions of 37.5%, 17.2%, and 5.2% with a comparison to a conventional OPO operating at repetition rates of 1, 2 and 3 MHz, respectively. Furthermore, the generated synchronized two-color laser sources at a low repetition rate were then employed to detect CH vibrational bands in an ethanol sample. This spectral tailored cavity design is expected to greatly promote the spread of compact all-fiber laser source to nonlinear biomedical imaging.
AB - All-fiber optical parametric oscillator (OPO), offering advantages like robustness, compactness and low lost, has attracted intense interest in coherent anti-Stokes Raman scattering spectroscopy. In typical fiber-based OPO configurations, detrimental nonlinear effects due to intense pump field in fiber coupling devices would inevitably degrade the spectral purity and conversion efficiency, especially when the OPO operated at low repetition rates. Here we demonstrated a new OPO design by placing the main amplifier inside the cavity, where the amplified pump pulses were directly coupled into the nonlinear fiber. Consequently, lower threshold, higher output power and narrower spectrum were obtained. In particular, effective suppression of spectral noise was experimentally observed, resulting in threshold reductions of 37.5%, 17.2%, and 5.2% with a comparison to a conventional OPO operating at repetition rates of 1, 2 and 3 MHz, respectively. Furthermore, the generated synchronized two-color laser sources at a low repetition rate were then employed to detect CH vibrational bands in an ethanol sample. This spectral tailored cavity design is expected to greatly promote the spread of compact all-fiber laser source to nonlinear biomedical imaging.
UR - https://www.scopus.com/pages/publications/85048958234
U2 - 10.1364/OE.26.017519
DO - 10.1364/OE.26.017519
M3 - 文章
C2 - 30119563
AN - SCOPUS:85048958234
SN - 1094-4087
VL - 26
SP - 17519
EP - 17528
JO - Optics Express
JF - Optics Express
IS - 13
ER -