Skip to main navigation Skip to search Skip to main content

Integration and first operation of the Gotthard-II detector at European XFEL

  • Marco Ramilli*
  • , Karim Ahmed
  • , Raphael de Wijn
  • , Thomas Dietze
  • , Bruno Fernandes
  • , David Hammer
  • , Yifeng Jiang
  • , Dmitry Khakhulin
  • , Jayanath C.P. Koliyadu
  • , Romain Letrun
  • , Jia Liu
  • , Carlos Lopez-Cuenca
  • , Davide Mezza
  • , Christopher Milne
  • , Aldo Mozzanica
  • , Andrea Parenti
  • , Tokushi Sato
  • , Philipp Schmidt
  • , Bernd Schmitt
  • , Marcin Sikorski
  • Monica Turcato, Yohei Uemura, Hao Wang, Hazem Yousef, Jiaguo Zhang
*Corresponding author for this work
  • European XFEL
  • Paul Scherrer Institute

Research output: Contribution to journal › Article › peer-review

Abstract

Gotthard-II (G-II) is a 1-D silicon microstrip hybrid detector developed by the Paul Scherrer Institut within the framework of a collaboration agreement with the European XFEL. The ASIC features a dynamic gain switching architecture, in order to cope with the luminosity of European XFEL, and a 12-bit analog-to-digital converter with a sampling/conversion rate of more than 18 MS/s as well as a Static random-access memory, making it capable of matching the European XFEL pulse train structure, thus acquiring up to 2700 images at 4.5 MHz per burst. The sensor's strip pitch can be either of 50 μm or 25 μm, for a total of 1280 or 2560 output channels per detector, respectively, with a spectral sensitivity that allows either X-ray detection (optimized in the 5–20 keV range) or visible light detection. Its exceptionally good compliance with the European XFEL beam conditions will make G-II the most widely employed detector across the facility, with a total of 29 modules of different flavors that will be installed in scientific instruments and beam diagnostic setups. Although the detector will be predominantly used for spectroscopic measurements it will have a variety of other applications, including X-ray diffraction/emission/absorption experiments, relative pulse arrival time monitoring (of fundamental importance for pump–probe experiments), spectral diagnostics, and beam quality monitoring, with the possibility for the detector itself to generate a veto patterns for the large area MHz framerate pixel detectors employed at the scientific instruments, such as AGIPD, LPD and DSSC. In this paper, an overview of G-II detector technology and its usage at the European XFEL will be presented; the focus will then move on towards the process of detector integration in the European XFEL control system, data acquisition, and data correction infrastructure, highlighting its challenges. Finally, an overview of the first results obtained at scientific instruments will be given.

Original languageEnglish
Article number168796
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume1058
DOIs
StatePublished - Jan 2024
Externally publishedYes

Keywords

  • Calibration
  • FEL
  • Integration
  • MHz detectors
  • X-ray detectors

Fingerprint

Dive into the research topics of 'Integration and first operation of the Gotthard-II detector at European XFEL'. Together they form a unique fingerprint.

Cite this