TY - JOUR
T1 - Field measurement of emission factors of PM, EC, OC, parent, nitro-, and oxy- polycyclic aromatic hydrocarbons for residential briquette, coal cake, and wood in rural Shanxi, China
AU - Shen, Guofeng
AU - Tao, Shu
AU - Wei, Siye
AU - Chen, Yuanchen
AU - Zhang, Yanyan
AU - Shen, Huizhong
AU - Huang, Ye
AU - Zhu, Dan
AU - Yuan, Chenyi
AU - Wang, Haochen
AU - Wang, Yafei
AU - Pei, Lijun
AU - Liao, Yilan
AU - Duan, Yonghong
AU - Wang, Bin
AU - Wang, Rong
AU - Lv, Yan
AU - Li, Wei
AU - Wang, Xilong
AU - Zheng, Xiaoying
PY - 2013/3/19
Y1 - 2013/3/19
N2 - Air pollutants from residential solid fuel combustion are attracting growing public concern. Field measured emission factors (EFs) of various air pollutants for solid fuels are close to the reality and urgently needed for better emission estimations. In this study, emission factors of particulate matter (PM), organic carbon (OC), elemental carbon (EC), and various polycyclic aromatic hydrocarbons (PAHs) from residential combustions of coal briquette, coal cake, and wood were measured in rural Heshun County, China. The measured EFs of PM, OC, and EC were 8.1-8.5, 2.2-3.6, 0.91-1.6 g/kg for the wood burnt in a simple metal stove, 0.54-0.64, 0.13-0.14, 0.040-0.0041 g/kg for the briquette burned in an improved stove with a chimney, and 3.2-8.5, 0.38-0.58, 0.022-0.052 g/kg for the homemade coal cake combusted in a brick stove with a flue, respectively. EFs of 28 parent PAHs, 4 oxygenated PAHs, and 9 nitro-PAHs were 182-297, 7.8-10, 0.14-0.55 mg/kg for the wood, 14-16, 1.7-2.6, 0.64-0.83 mg/kg for the briquette, and 168-223, 4.7-9.5, 0.16-2.4 mg/kg for the coal cake, respectively. Emissions from the wood and coal cake combustions were much higher than those for the coal briquette, especially true for high molecular weight PAHs. Most EFs measured in the field were higher than those measured in stove combustions under laboratory conditions.
AB - Air pollutants from residential solid fuel combustion are attracting growing public concern. Field measured emission factors (EFs) of various air pollutants for solid fuels are close to the reality and urgently needed for better emission estimations. In this study, emission factors of particulate matter (PM), organic carbon (OC), elemental carbon (EC), and various polycyclic aromatic hydrocarbons (PAHs) from residential combustions of coal briquette, coal cake, and wood were measured in rural Heshun County, China. The measured EFs of PM, OC, and EC were 8.1-8.5, 2.2-3.6, 0.91-1.6 g/kg for the wood burnt in a simple metal stove, 0.54-0.64, 0.13-0.14, 0.040-0.0041 g/kg for the briquette burned in an improved stove with a chimney, and 3.2-8.5, 0.38-0.58, 0.022-0.052 g/kg for the homemade coal cake combusted in a brick stove with a flue, respectively. EFs of 28 parent PAHs, 4 oxygenated PAHs, and 9 nitro-PAHs were 182-297, 7.8-10, 0.14-0.55 mg/kg for the wood, 14-16, 1.7-2.6, 0.64-0.83 mg/kg for the briquette, and 168-223, 4.7-9.5, 0.16-2.4 mg/kg for the coal cake, respectively. Emissions from the wood and coal cake combustions were much higher than those for the coal briquette, especially true for high molecular weight PAHs. Most EFs measured in the field were higher than those measured in stove combustions under laboratory conditions.
UR - https://www.scopus.com/pages/publications/84875312962
U2 - 10.1021/es304599g
DO - 10.1021/es304599g
M3 - 文章
C2 - 23419187
AN - SCOPUS:84875312962
SN - 0013-936X
VL - 47
SP - 2998
EP - 3005
JO - Environmental Science and Technology
JF - Environmental Science and Technology
IS - 6
ER -