TY - JOUR
T1 - Effect of diluting agent on sensitivity in capillary electrophoresis with amperometric detection
AU - Wang, Qiangjiang
AU - Ding, Fei
AU - Li, Hui
AU - He, Pingang
AU - Fang, Yuzhi
PY - 2003/5
Y1 - 2003/5
N2 - Besides the running buffer, pH of buffer, separation voltage and sampling time, the diluting agent was studied in this paper as one of the important factors influencing the sensitivity in capillary electrophoresis (CE) with amperometric detection (AD) when electrokinectic sampling was used. Clonidine hydrochloride, hydrochlorothiazide and rutin, which are positively charged, neutral and negatively charged, respectively, in aqueous solutions, could be perfectly separated by CE with 25 mmol·L-1 Na2B4O7-50 mmol·L-1 NaH2PO4 as running buffer and detected by measuring their current responses with AD. Before CE running, some kinds of diluents including water, methanol, formamide, running buffer, hydrochloric acid and sodium hydroxide were, respectively, applied to dilute the stock solutions of above three analytes and their effects on the sensitivity of CE-AD were investigated. The results showed that for electrokinetic injection, the current responses of these three analytes were greatly affected in different ways when different diluting agents were used. This method was applied to simultaneously determine the active ingredients in one Chinese compound hypotensor named Zhen Ju Jiang Ya Pian, in which the contents of clonidine hydrochloride, hydrochlorothiazide and rutin is very different as 0.03 mg : 5 mg : 20 mg per tablet, and satisfactory results were obtained by adjusting their sensitivity by selecting the suitable diluting agent.
AB - Besides the running buffer, pH of buffer, separation voltage and sampling time, the diluting agent was studied in this paper as one of the important factors influencing the sensitivity in capillary electrophoresis (CE) with amperometric detection (AD) when electrokinectic sampling was used. Clonidine hydrochloride, hydrochlorothiazide and rutin, which are positively charged, neutral and negatively charged, respectively, in aqueous solutions, could be perfectly separated by CE with 25 mmol·L-1 Na2B4O7-50 mmol·L-1 NaH2PO4 as running buffer and detected by measuring their current responses with AD. Before CE running, some kinds of diluents including water, methanol, formamide, running buffer, hydrochloric acid and sodium hydroxide were, respectively, applied to dilute the stock solutions of above three analytes and their effects on the sensitivity of CE-AD were investigated. The results showed that for electrokinetic injection, the current responses of these three analytes were greatly affected in different ways when different diluting agents were used. This method was applied to simultaneously determine the active ingredients in one Chinese compound hypotensor named Zhen Ju Jiang Ya Pian, in which the contents of clonidine hydrochloride, hydrochlorothiazide and rutin is very different as 0.03 mg : 5 mg : 20 mg per tablet, and satisfactory results were obtained by adjusting their sensitivity by selecting the suitable diluting agent.
KW - Amperometric detection
KW - Capillary electrophoresis
KW - Diluting agent
KW - Sensitivity
UR - https://www.scopus.com/pages/publications/0346504207
U2 - 10.1002/elps.200305393
DO - 10.1002/elps.200305393
M3 - 文章
C2 - 12761800
AN - SCOPUS:0346504207
SN - 0173-0835
VL - 24
SP - 1687
EP - 1692
JO - Electrophoresis
JF - Electrophoresis
IS - 10
ER -