Skip to main navigation Skip to search Skip to main content

Development of a Photoacoustic Platform for Blood Glucose Monitoring and a Comparative Study between Signal Propagation delay and Peak-to-Peak Amplitude

  • Jianyu Zhang
  • , Zhizhang Li
  • , Luohan Lin
  • , Guoxing Wang*
  • , Cheng Chen*
  • *Corresponding author for this work
  • Shanghai Jiao Tong University

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

Abstract

Achieving noninvasive glucose monitoring is a critical goal for diabetes management, and photoacoustic (PA) technology has emerged as a promising pathway. However, conventional PA-glucose models based on the peak-to-peak amplitude (VPP) are often compromised by environmental interference. While the signal propagation delay (TP) has shown empirical promise for more stable measurements, a foundational theoretical analysis of its robustness has been absent. This study fills this gap, first by presenting a theoretical analysis concluding that TP is inherently more robust against environmental noise than VPP, and then by providing experimental validation on a custom-built PA platform. Linear regression models for both features were established over a 0-1452 mg/dL concentration range. The resulting TP model demonstrated a significantly better goodness-of-fit (R2=0.874) compared to the VPP model (R2=0.671). Furthermore, validation on an independent dataset confirmed the TP's superiority: Clarke Error Grid (CEG) analysis showed 100% of readings in the clinically acceptable A+B zones, starkly outperforming the 70% from the VPP-based approach. Our findings provide the first theoretical and experimental evidence for the superiority of TP, positioning it as a more robust feature for reliable noninvasive PA-based glucose monitoring.

Original languageEnglish
Title of host publicationISCAS 2026 - 2026 IEEE International Symposium on Circuits and Systems
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages3551-3555
Number of pages5
ISBN (Electronic)9798331577698
DOIs
StatePublished - 2026
Externally publishedYes
Event2026 IEEE International Symposium on Circuits and Systems, ISCAS 2026 - Shanghai, China
Duration: 24 May 2026 → 27 May 2026

Publication series

NameProceedings - IEEE International Symposium on Circuits and Systems
ISSN (Print)0271-4310

Conference

Conference2026 IEEE International Symposium on Circuits and Systems, ISCAS 2026
Country/TerritoryChina
CityShanghai
Period24/05/26 → 27/05/26

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Features extraction
  • Interference suppression
  • Noninvasive glucose monitoring
  • Photoacoustic

Fingerprint

Dive into the research topics of 'Development of a Photoacoustic Platform for Blood Glucose Monitoring and a Comparative Study between Signal Propagation delay and Peak-to-Peak Amplitude'. Together they form a unique fingerprint.