Abstract
A Pt microelectrode modified with nickel(II) polytetramethyldibenzo[b,i]tetraaza[14]annulene was prepared by electropolymerization of nickel(II) tetramethyldibenzo[b,i]tetraaza[14]annulene monomers and applied to determine sulfur dioxide in vitriol plant wastewater. For determination of SO2 with this electrochemically modified. Pt microelectrode, the linear range was from 9.6 × 10-6 to 2.4 × 10-4 mol L-1, the sensitivity was 1.8 × 10-4 A L mol-1, the detection limit was calculated to be 4.8 × 10-6 mol L-1 (S/N = 3), the response time was less than 20 s and the relative standard deviation was found to be 2.1% on analyzing 4.8 × 10-5 mol -1 SO2 solution repeatedly (n = 7). These results demonstrated good accuracy compared with those obtained by the conventional iodimetric method.
| Original language | English |
|---|---|
| Pages (from-to) | 669-672 |
| Number of pages | 4 |
| Journal | Analyst |
| Volume | 126 |
| Issue number | 5 |
| DOIs | |
| State | Published - 2001 |