N2 - To achieve the simultaneous and unobtrusive breathing rate (BR) and heart rate (HR) measurements during nighttime, we leverage a far-infrared imager and an infrared camera equipped with IR-Cut lens and an infrared lighting array to develop a dual-camera imaging system. A custom-built cascade face classifier, containing the conventional Adaboost model and fully convolutional network trained by 32K images, was used to detect the face region in registered infrared images. The region of interest (ROI) inclusive of mouth and nose regions was afterwards confirmed by the discriminative regression and coordinate conversions of three selected landmarks. Subsequently, a tracking algorithm based on spa-tio-temporal context learning was applied for following the ROI in thermal video, and the raw signal was synchronously extracted. Finally, a custom-made time-domain signal analysis approach was developed for the determinations of BR and HR. A dual-mode sleep video database, including the videos obtained under environment where illumination intensity ranged from 0 to 3 Lux, was constructed to evaluate the effectiveness of the proposed system and algorithms. In linear regression analysis, the determination coefficient (R2) of 0.831 had been observed for the measured BR and reference BR, and this value was 0.933 for HR measurement. In addition, the Bland-Altman plots of BR and HR demonstrated that almost all the data points located within their own 95% limits of agreement. Consequently, the overall performance of the proposed technique is acceptable for BR and HR estimations during nighttime.
AB - To achieve the simultaneous and unobtrusive breathing rate (BR) and heart rate (HR) measurements during nighttime, we leverage a far-infrared imager and an infrared camera equipped with IR-Cut lens and an infrared lighting array to develop a dual-camera imaging system. A custom-built cascade face classifier, containing the conventional Adaboost model and fully convolutional network trained by 32K images, was used to detect the face region in registered infrared images. The region of interest (ROI) inclusive of mouth and nose regions was afterwards confirmed by the discriminative regression and coordinate conversions of three selected landmarks. Subsequently, a tracking algorithm based on spa-tio-temporal context learning was applied for following the ROI in thermal video, and the raw signal was synchronously extracted. Finally, a custom-made time-domain signal analysis approach was developed for the determinations of BR and HR. A dual-mode sleep video database, including the videos obtained under environment where illumination intensity ranged from 0 to 3 Lux, was constructed to evaluate the effectiveness of the proposed system and algorithms. In linear regression analysis, the determination coefficient (R2) of 0.831 had been observed for the measured BR and reference BR, and this value was 0.933 for HR measurement. In addition, the Bland-Altman plots of BR and HR demonstrated that almost all the data points located within their own 95% limits of agreement. Consequently, the overall performance of the proposed technique is acceptable for BR and HR estimations during nighttime.
UR - https://www.scopus.com/pages/publications/85040102183
U2 - 10.1371/journal.pone.0190466
DO - 10.1371/journal.pone.0190466
M3 - 文章
C2 - 29304152
AN - SCOPUS:85040102183
SN - 1932-6203
VL - 13
JO - PLoS ONE
JF - PLoS ONE
IS - 1
M1 - e0190466
ER -