TY - JOUR
T1 - Cause and pre-alarm control of bulking and foaming by Microthrix parvicella-A case study in triple oxidation ditch at a wastewater treatment plant
AU - Xie, B.
AU - Dai, X. C.
AU - Xu, Y. T.
PY - 2007/5/8
Y1 - 2007/5/8
N2 - The cause and control of foaming and bulking in triple oxidation ditch at a wastewater treatment plant (WWTP) were investigated. The results showed that the foaming and bulking was mainly caused by the excessive propagation of Microthrix parvicella, and mostly occurred in the cold winter and spring. Batch and continuous flow experiments indicated that biological techniques such as reducing sludge retention time (SRT) and increasing F/M ratio, chemical methods such as addition of chlorine (NaOCl), quaternary ammonium salt (QAS), or cationic polyacrylamide flocculants (PAM), polyaluminum salt (PAC) could decrease Sludge Volume Index (SVI) and control foaming and bulking at different levels. In practical application, the shorter SRT was effective to control foaming and bulking in initial stage, although it took longer time. Addition of 10 g Cl kg MLSS d-1 could gradually change the activated sludge with serious foaming and bulking to normal state within a week. Pre-alert control strategies should be established for the control of filamentous foaming and bulking.
AB - The cause and control of foaming and bulking in triple oxidation ditch at a wastewater treatment plant (WWTP) were investigated. The results showed that the foaming and bulking was mainly caused by the excessive propagation of Microthrix parvicella, and mostly occurred in the cold winter and spring. Batch and continuous flow experiments indicated that biological techniques such as reducing sludge retention time (SRT) and increasing F/M ratio, chemical methods such as addition of chlorine (NaOCl), quaternary ammonium salt (QAS), or cationic polyacrylamide flocculants (PAM), polyaluminum salt (PAC) could decrease Sludge Volume Index (SVI) and control foaming and bulking at different levels. In practical application, the shorter SRT was effective to control foaming and bulking in initial stage, although it took longer time. Addition of 10 g Cl kg MLSS d-1 could gradually change the activated sludge with serious foaming and bulking to normal state within a week. Pre-alert control strategies should be established for the control of filamentous foaming and bulking.
KW - Filamentous bacteria
KW - Foaming and bulking
KW - Microthrix parvicella
KW - Pre-alarm control
KW - Triple oxidation ditch
UR - https://www.scopus.com/pages/publications/34147155378
U2 - 10.1016/j.jhazmat.2006.09.006
DO - 10.1016/j.jhazmat.2006.09.006
M3 - 文章
C2 - 17049735
AN - SCOPUS:34147155378
SN - 0304-3894
VL - 143
SP - 184
EP - 191
JO - Journal of Hazardous Materials
JF - Journal of Hazardous Materials
IS - 1-2
ER -