TY - JOUR
T1 - Automated Ultrasound Measurement of the Inferior Vena Cava
T2 - An Animal Study
AU - Chen, Jiangang
AU - Li, Jiawei
AU - Ding, Xin
AU - Wei, Gaofeng
AU - Wang, Xiaoting
AU - Li, Qingli
N1 - Publisher Copyright:
© The Author(s) 2020.
PY - 2020/5/1
Y1 - 2020/5/1
N2 - Because of continuous movement and variation in diameter of the inferior vena cava (IVC) with respiration, the measurements on IVC are labor-intensive and with considerable inter-operator variations. Some computer-assisted techniques have been developed to track the movement of the IVC semi-automatically. However, existing methods predominantly rely on reference marker selection and require many manual inputs. In this study, we developed a cross-correlation (CC)-based method for automated IVC movement tracking and measurement, which requires minimal manual input and avoids manual selection of reference markers. Based on the CC method, two approaches, named direct and relative approaches, were used to calculate the maximum, minimum, and variation of the IVC diameter, and compared with the manual measurement. Fifty-four ultrasound cine-loops collected from nine pigs were tested. The results reveal that both the proposed approaches were well agreed with the manual measurement. The errors of the direct approach were less than 9%, while those of relative approach were as high as 26.7%. It is concluded that the proposed direct approach is superior for IVC diameter measurements, which can be comparable with manual counterpart, serving as an alternative to traditional IVC measurement.
AB - Because of continuous movement and variation in diameter of the inferior vena cava (IVC) with respiration, the measurements on IVC are labor-intensive and with considerable inter-operator variations. Some computer-assisted techniques have been developed to track the movement of the IVC semi-automatically. However, existing methods predominantly rely on reference marker selection and require many manual inputs. In this study, we developed a cross-correlation (CC)-based method for automated IVC movement tracking and measurement, which requires minimal manual input and avoids manual selection of reference markers. Based on the CC method, two approaches, named direct and relative approaches, were used to calculate the maximum, minimum, and variation of the IVC diameter, and compared with the manual measurement. Fifty-four ultrasound cine-loops collected from nine pigs were tested. The results reveal that both the proposed approaches were well agreed with the manual measurement. The errors of the direct approach were less than 9%, while those of relative approach were as high as 26.7%. It is concluded that the proposed direct approach is superior for IVC diameter measurements, which can be comparable with manual counterpart, serving as an alternative to traditional IVC measurement.
KW - automated measurement
KW - inferior vena cava
KW - ultrasound
KW - vessel identification
KW - vessel localization
UR - https://www.scopus.com/pages/publications/85083062289
U2 - 10.1177/0161734620912345
DO - 10.1177/0161734620912345
M3 - 文章
C2 - 32238107
AN - SCOPUS:85083062289
SN - 0161-7346
VL - 42
SP - 148
EP - 158
JO - Ultrasonic Imaging
JF - Ultrasonic Imaging
IS - 3
ER -