TY - JOUR
T1 - Assessing the matrix effects on MALDI-MS in the positive and negative ion mode detection for protein-protected metal nanoclusters
AU - Yuan, Hao
AU - Lima, Djibril
AU - Comby-Zerbino, Clothilde
AU - Bouanchaud, Charlène
AU - Chirot, Fabien
AU - Bain, Dipankar
AU - Zhang, Sanjun
AU - Antoine, Rodolphe
N1 - Publisher Copyright:
© 2024 The Authors
PY - 2024/9
Y1 - 2024/9
N2 - Protein-protected metal nanoclusters (MNCs) represent a new class of highly photoluminescent nanomaterials that have wide applications. Suitable reaction conditions combining protein and metal precursors can produce a vast range of different NC sizes (i.e. different number of metal atoms). The average number of metal atoms per protein can be determined by mass spectrometry (MS). MS coupled with matrix-assisted laser desorption ionization (MALDI) presents a number of advantages such as detection with high sensitivity of nanoclusters with high molecular weights. Although many protein-protected MNCs have been characterized by MALDI-MS, a large dispersion in the number of metal atoms has been reported mainly due to sample preparation. In this work, we optimized the protocols for negative and positive ion detection mode as a general MALDI-MS sample preparation method for protein-protected MNCs (bovine serum albumin and lysozyme and with gold and silver). Negative and positive ion mode detection was compared, showing that negative ion mode detection in MALDI-MS can also be used with acidic matrices. Obvious matrix effects on ion signals and peak positions by MALDI-MS were observed. The average metal numbers of MNCs embedded in proteins are different depending on the MALDI matrix. The matrix effects give a warning for more serious consideration on MALDI-MS measurement and spectra analysis of MNCs.
AB - Protein-protected metal nanoclusters (MNCs) represent a new class of highly photoluminescent nanomaterials that have wide applications. Suitable reaction conditions combining protein and metal precursors can produce a vast range of different NC sizes (i.e. different number of metal atoms). The average number of metal atoms per protein can be determined by mass spectrometry (MS). MS coupled with matrix-assisted laser desorption ionization (MALDI) presents a number of advantages such as detection with high sensitivity of nanoclusters with high molecular weights. Although many protein-protected MNCs have been characterized by MALDI-MS, a large dispersion in the number of metal atoms has been reported mainly due to sample preparation. In this work, we optimized the protocols for negative and positive ion detection mode as a general MALDI-MS sample preparation method for protein-protected MNCs (bovine serum albumin and lysozyme and with gold and silver). Negative and positive ion mode detection was compared, showing that negative ion mode detection in MALDI-MS can also be used with acidic matrices. Obvious matrix effects on ion signals and peak positions by MALDI-MS were observed. The average metal numbers of MNCs embedded in proteins are different depending on the MALDI matrix. The matrix effects give a warning for more serious consideration on MALDI-MS measurement and spectra analysis of MNCs.
KW - Matrix effects
KW - Matrix-assisted laser desorption ionization mass spectrometry
KW - Positive/negative ion mode detection
KW - Protein-protected metal nanoclusters
KW - gold
KW - proteins
KW - silver
UR - https://www.scopus.com/pages/publications/85195419122
U2 - 10.1016/j.ijms.2024.117276
DO - 10.1016/j.ijms.2024.117276
M3 - 文章
AN - SCOPUS:85195419122
SN - 1387-3806
VL - 503
JO - International Journal of Mass Spectrometry
JF - International Journal of Mass Spectrometry
M1 - 117276
ER -