TY - JOUR
T1 - A new microdialysis-electrochemical device for in vivo simultaneous determination of acetylcholine and choline in rat brain treated with N-methyl-(R)-salsolinol
AU - Zhu, Wei
AU - An, Yarui
AU - Zheng, Jiaohong
AU - Tang, Linlin
AU - Zhang, Wen
AU - Jin, Litong
AU - Jiang, Lai
PY - 2009/8/15
Y1 - 2009/8/15
N2 - Acetylcholine (ACh) and choline (Ch) play a critical role in cholinergic neurotransmission and the abnormalities in their concentrations are related to several neural diseases. Therefore, the in vivo determination of ACh and Ch is important to the research on neurodegenerative disorders. In this work, electrochemical biosensors based on poly(m-(1,3)-phenylenediamine) (pmPD) and polytyramine (PTy) modified enzyme electrodes were fabricated. The electropolymerized pmPD polymer was used to exclude interfering substances and the PTy layer facilitated the immobilization of acetylcholinesterase (AChE) and choline oxidase (ChOx). Then, ACh/Ch sensor and Ch sensor were coupled with microdialysis to produce a novel device, which provides a sensitive and selective method for simultaneous determination of ACh and Ch. This method has detection limits of 63.0 ± 3.4 nM for ACh and 25.0 ± 1.2 nM for Ch. The integrated device was successfully applied to assessing the impact of endogenous neurotoxin N-methyl-(R)-salsolinol [1(R),2-dimethyl-6,7-dihydroxy-1,2,3,4-tetrahydroisoquinoline, (R)-NMSal] on ACh and Ch concentration, which is of great benefit to understand the pathogenesis of Parkinson's disease.
AB - Acetylcholine (ACh) and choline (Ch) play a critical role in cholinergic neurotransmission and the abnormalities in their concentrations are related to several neural diseases. Therefore, the in vivo determination of ACh and Ch is important to the research on neurodegenerative disorders. In this work, electrochemical biosensors based on poly(m-(1,3)-phenylenediamine) (pmPD) and polytyramine (PTy) modified enzyme electrodes were fabricated. The electropolymerized pmPD polymer was used to exclude interfering substances and the PTy layer facilitated the immobilization of acetylcholinesterase (AChE) and choline oxidase (ChOx). Then, ACh/Ch sensor and Ch sensor were coupled with microdialysis to produce a novel device, which provides a sensitive and selective method for simultaneous determination of ACh and Ch. This method has detection limits of 63.0 ± 3.4 nM for ACh and 25.0 ± 1.2 nM for Ch. The integrated device was successfully applied to assessing the impact of endogenous neurotoxin N-methyl-(R)-salsolinol [1(R),2-dimethyl-6,7-dihydroxy-1,2,3,4-tetrahydroisoquinoline, (R)-NMSal] on ACh and Ch concentration, which is of great benefit to understand the pathogenesis of Parkinson's disease.
KW - (R)-NMSal
KW - Acetylcholine
KW - Choline
KW - Electrochemical
KW - Microdialysis
UR - https://www.scopus.com/pages/publications/67650076661
U2 - 10.1016/j.bios.2009.05.023
DO - 10.1016/j.bios.2009.05.023
M3 - 文章
C2 - 19523811
AN - SCOPUS:67650076661
SN - 0956-5663
VL - 24
SP - 3594
EP - 3599
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
IS - 12
ER -