有源降噪入耳式耳机声衰减实验测量及对比研究

Translated title of the contribution: Experimental measurement and comparative study of sound attenuation measurement methods of active noise reduction insert earphones

Xiaolin Wu, Xiaobin Cheng, Jinqiu Sang, Xiaodong Li

Research output: Contribution to journalArticlepeer-review

Abstract

For the measurement of sound attenuation of active noise reduction insert earphones, four typical measurement methods are comparatively studied, including real-ear attenuation at threshold (REAT), loudness balance (LB), microphone-in-real-ear (MIRE), and acoustic test fixture (ATF) methods. According to the characteristics of the earphones, the measurement devices, experimental environment, and experimental procedures are designed, and the measurement studies of three earphones are carried out. The results show that for passive sound attenuation measurements, the results of the MIRE method are close to those of the “gold” standard—REAT method in the middle and high frequency range, with a difference of ±3 dB, and more accurate at low frequencies. For active sound attenuation measurements, the results of the MIRE and LB methods are close to each other, with a difference of ±2 dB, and the MIRE method is easier to operate. The MIRE method has high test efficiency and accuracy and is an effective method to measure the sound attenuation of active noise reduction insert earphones.

Translated title of the contributionExperimental measurement and comparative study of sound attenuation measurement methods of active noise reduction insert earphones
Original languageChinese (Traditional)
Pages (from-to)577-586
Number of pages10
JournalShengxue Xuebao/Acta Acustica
Volume49
Issue number3
DOIs
StatePublished - May 2024

Fingerprint

Dive into the research topics of 'Experimental measurement and comparative study of sound attenuation measurement methods of active noise reduction insert earphones'. Together they form a unique fingerprint.